SHOW STATUS (SHO ST)

Qualifiers:

< alarm category>

ALARMS

ALARMS ALL

REDUNDANT

RAID

Purpose:

Provides all alarm information for the specified alarm.

Details:

Refer to the available alarm categories and alarm thresholds.  

REDUNDANT qualifier applies only to the CX II, CXi II, MXe and MXe Server fan, power supply, and hard drive. Use it to identify which redundant hardware component has failed. The system response varies depending upon whether the controller is equipped with SATA hard drives (MXe III) or PATA hard drives (all other controllers).

On the SUPERCONSOLE 1000, this command is found under the REPORTS group of commands.

RAID qualifier applies only to an MXe III equipped with a RAID controller. Use it to debug the RAID controller and identify the following:

Examples:

Entry: SHOW STATUS ALARMS

System Response:

Current System :  Alarm Major : viewed from Active

Category

Total in System

Unavailable

Alarm Threshold Percentage

Total

%

Alarm

Minor

Major

Critical

Digital Links

1

1

100

Major

-

>0%

-

Entry: SHOW STATUS SFT ZONES

System Response:

Category

Total in System

Unavailable

Alarm Threshold Percentage

Total

%

Alarm

Minor

Major

Critical

SFT Zones

1

0

0

 

-

>0%

100%

Entry: SHOW STATUS REDUNDANT

System Response (MXe II or MXe Server with PATA hard drives):

Power Supply

 

Installed

Seated Fault

Input Fault

Output Fault

Temp. Fault

Fan Fault

1

Yes

No

No

No

No

No

2

Yes

No

No

No

No

No

 

 

 

 

 

 

 


Fan

Running

1

Yes

2

Yes


Temperature Sensor

Temperature

Alarmed

1

26

No

2

29

No

 

 

 

 

RAID controller temperature 26. RAID Temperature Alarm Inactive.

RAID controller rebuild is idle.

Hard Disk

 

Installed

Hard Fault

Soft Fault

1

Yes

No

No

2

Yes

No

No

 System Response (MXe III with SATA hard drives):

Power Supply

 

Installed

Seated Fault

Input Fault

Output Fault

Temp. Fault

Fan Fault

1

Yes

No

No

No

No

No

2

Yes

No

No

No

No

No

 

 

 

 

 

 

 


Fan

Running

1

Yes

2

Yes


Temperature Sensor

Temperature

Alarmed

1

26

No

2

29

No

 

 

 

 

RAID controller temperature 26. RAID Temperature Alarm Inactive.

RAID controller rebuild is idle.

Hard Disk

 

Installed

Hard Fault

Disk State

Disk Status

1

Yes

No

Normal

Match

2

Yes

No

Normal

Match

Entry: SHOW STATUS RAID

System Response (MXe III with RAID controller):

RAID Type

:

Silicon Image 5923

RAID Mode

:

RAID1 SAFE

Currently Rebuilding

:

YES

Last LBA Rebuild

:

284619520  91% complete

 

  HOST
------

HD1
-------

HD2
-------

Link Speed 1.5g SATA I

3G SATA II

3G SATA II

Link Detect status OKAY

OKAY

OKAY

 

 

HD1
-------

HD2
-------

NVM Device State Rebuilding Good
Device State Rebuilding Good
Device Status SN Matches SN Matches
Match Status SN Matches SN Matches

 

Raid Size

:

160041885696 bytes

HD 1 Drive Capacity

:

160041885696 bytes

HD 2 Drive Capacity

:

160041885696 bytes

 

HD 1 Expected Model Number : ST9160314AS
  Current Model Number : ST9160314AS
HD 2 Expected Model Number : WDC WD1600BEVT-00ZCT0
  Current Model Number : WDC WD1600BEVT-00ZCT0
HD 1 Expected Serial Number : 5VC1Q63N
  Current Serial Number : 5VC1Q63N
HD 2 Expected Serial Number : WD-WXC409818785
  Current Serial Number : WD-WXC409818785

 

Error Logs from Sil5923:
0: Empty
1: Empty
2: Empty
3: Empty